Whisperflo flow rate problem
I was working on a pool filtration system today for a condominium association in Huntington Beach. It had 3" plumbing feeding two identical 2 HP Pentair whisperflo pumps on a 70000 gallon swimming pool. One was making a lot of noise so I checked and replaced the pump...
Aqua Rite Flo Switch Problem
Today I was in Huntington Beach looking at a Hayward - Goldline Aqua Rite?salt chlorine generator with a No flow error. Originally I thought that the?flow sensor was bad and replaced it. This solved the problem for only a few?minutes, then the flow indicator light...
Pentair Mastertemp Heater E05 error
I was called out to look at a Pentair MasterTemp 400 pool heater in Newport Beach today. After running for about 15 minutes, the display showed E05. Diagnostics registered stack flu sensor error. The stack flue sensor shuts the heater off if exhaust gasses exceed 500...
Jandy FloPro VS
I put a new control board into a Jandy Aqualink RS 6 that was about 15 years old in Huntington Beach yesterday. I am replacing the entire equipment system and originally I was going to install all Hayward products which I really like, including an Ecostar variable...
WFE-6 Pump Seal replace & Pentair slide valve rebuild
I've decided to write summaries of pool repairs and new equipment installs to give pool owners in Orange County a better idea of the types of services I offer. ?This morning I replaced a leaking pump seal on ?a Pentair Whisperflo WFE-6 pool pump in Huntington Beach....
Hayward Ecostar Variable Speed Pump replacement
Here's the Hayward Ecostar Variable Speed pump (Top). Saves tons of money on Electricity and is a drop-in replacement for other Hayward pumps. Below is the Hayward Super 2 it replaced. You can see they are almost the same size, and the plumbing configuration is the...